Quick return of the temperature to the set temperature after opening the device door
Better Uniformity and faster heating with the second-generation HCT
Uniformity @ 27 points of the chamber
Temperature stability
dual chamber
According to the latest standards of (TWW) DIN 12880 Class 3.1
Adjustable safety thermostat with separate sensor
Temperature control in case of unwanted increase
Two PT100 sensors
To get to know More details about FG laboratory Oven Watch the opposite video.




Tray made of mesh stainless steel sheet
Manufacturing based on custom dimensions and temperatures
Installation of valves in customized number and diameter
Glass door with metal frame
IQ, OQ, PQ Certificates
Calibration Certificate
Light bulb
net tray
No, the mechanism of the air release valve is the maximum exit of vapors and gases created in the chamber. But the circulator fan is used to accelerate the air circulation inside the chamber.
It always takes time for the internal chamber temperature to reach the set point. The Smart timer is activated when the temperature reaches the set point.
Using a safety thermostat in FG devices that acts like a fuse and turns off the incubator device if the temperature rises above the set point.
According to FG standards and valid world standards, the best distance from the walls, floor, and ceiling of the incubator is 10% of the length of the same side. And if the depth of the device is 50 cm, 10% of it, that is, 5 cm from the front and back, should be considered the distance from the walls of the device for loading.
Yes, with the help of the HCT technology used in the incubator, you will have full uniformity even when the device is fully loaded (in accordance with the loading principles).
The incubator device reaches the set point temperature as quickly as possible and the temperature gradient adjustment is to prolong the time for the chamber temperature to reach the set point temperature, as a result, the time for the chamber temperature to reach the set point temperature cannot be made faster.
Yes, it is possible to install sockets for FG incubators upon request.
Since incubators usually work at 5 degrees above the ambient temperature, this doubt arises for consumers that if the temperature of the laboratory environment is, for example, 20 degrees, a thermal incubator can be used for a temperature of 30 degrees. But since the temperature The environment cannot be controlled. The standards emphasize the use of a refrigerated incubator for temperatures close to the ambient temperature, because the ambient temperature may become hotter, and the incubator device must also be capable of cooling the chamber.
Yes, a special mechanism has been considered for the air evacuation process and the entry of fresh air into the incubator chamber, which causes the maximum evacuation of moisture and gases created in the chamber.
Yes, if needed, you can move the trays according to the different drawers installed in the incubator.
Yes, if needed, you can move the trays according to the different drawers installed in the oven.
No, if you need more trays in the incubator, you can use more space just by buying a tray, and there is no need to pay extra for installing rails or other changes in the device.