Smart Laboratory Incubator

Smart Laboratory Incubator

Introducing the new generation of FG Smart laboratory incubator

The most accurate incubator in the world with unique isotherm in accordance with the most reliable international standards

Fast temperature recovery to the set temperature after opening the door

Better temperature uniformity and faster heating with the second generation HCT

Temperature uniformity at 27 points in the chamber

Temperature stability

Triple-layered design

Double safety to protect your samples against unwanted increase or decrease in temperature

Compliant with the latest (TWW) DIN 12880 Class 3.1 standards

Adjustable safety thermostat with a separate sensor

Temperature control in case of unintended increase

Equipped with two PT100 sensors

Laboratory incubator introduction video

To get to knowMore details about FG laboratory ovenWatch the opposite video.

Product video gallery

Table of technical specifications laboratory incubator

External specifications
CM55
CM120
Minimum allowable distance from walls and adjacent devices (cm)
 
16
Minimum allowable distance from the back wall (cm)
 
10
10
Air discharge valve diameter (cm)
 
5
5
Depth (with handle and controller) (G) (cm)
 
60
73
Depth (without handle) (F) (cm)
 
54.5
67.5
Height of the device with stand (E) (cm)
 
63.5
68
Machine width (D) (cm)
 
64.5
82.5
Machine weight (kg)
 
43
61
Number of doors (number)
 
1
1
Internal specifications
CM55
CM120
Internal volume (Lit)
 
50
Height (B) (cm)
 
41.5
46
Width (A) (cm)
 
41
59
Depth (C) (cm)
 
29.5
42
Weight capacity for each tray (kg)
 
30
30
Total weight bearing capacity of floors (kg)
 
60
100
Number of standard trays available in the machine – (maximum)
 
2 – (4)
2 – (5)
Circulating fan
 
No
No
Heat information
CM55
CM120
Temperature range: 5 degrees above ambient temperature (minimum 20 degrees) to (C˚)
 
80°C
Display accuracy at temperature (deviation) (K±) 37°C
 
±0.2
±0.1
Display accuracy at temperature (deviation) (K±) 55°C
 
±0.2
±0.1
Display accuracy at temperature (deviation) (K±) 70°C
 
±0.1
±0.1
Temperature fluctuation (K±) 37°C
 
±0.2
±0.2
Temperature fluctuation (K±) 55°C
 
±0.2
±0.2
Temperature fluctuation (K±) 70°C
 
±0.2
±0.2
Temperature setting accuracy
 
±0.1
±0.1
Isothermal at 27 points of the chamber (Variation)
CM55
CM120
Isothermal variation (K±) at 37°C
 
±0.5
Isothermal at (variation) (K±) 55°C
 
±0.6
±0.6
Isothermal at (variation) (K±) 70°C
 
±0.7
±0.7
heating-up time*
CM55
CM120
Time to reach temperature (min) 37°C
 
55
Time to reach temperature (min) 55°C
 
95
Time to reach temperature (min) 70°C
 
100
Temperature returns to Set temperature after opening the appliance door for 30 seconds (*) (Recovery time)
CM55
CM120
Temperature return in (min) 37°C
 
35
Return temperature at (min) 55°C
 
35
35
Return temperature in (min) 70°C
 
40
45
Electrical information
CM55
CM120
Power consumption (W)
 
400
Frequency (HZ)
 
50
50
Voltage (VAC)
 
220
220
Current(A)
 
1.8
1.8
Type of electricity
 
Single phase
Single phase

Customized equipment and services

Perforated stainless steel tray

Custom dimensions and temperature options available

Installation of custom number and diameter of vents

Glass door with metal frame

IQ, OQ, PQ certifications

Calibration certificate provided

Built-in lighting

Mesh tray

No, the mechanism of the air release valve is the maximum exit of vapors and gases created in the chamber. But the circulator fan is used to accelerate the air circulation inside the chamber.

It always takes time for the internal chamber temperature to reach the set point. The smart timer is activated when the temperature reaches the set point.

Using a safety thermostat in FG devices, which acts like a fuse and turns off the incubator if the temperature exceeds the set point.

According to FG standards and the world’s valid standards, the best distance from the walls, floor and ceiling of the incubator is 10% of the length of the same side, for example, if the width of the device is 40 cm, 10% is 4 cm on each side (left and right). And if the depth of the device is 50 cm, 10% of it, that is, 5 cm from the front and back, should be considered the distance from the walls of the device for loading.

Yes, with the help of the HCT technology used in the incubator, you will have full isothermal even in the full load mode of the device (according to the loading principles).

The incubator device reaches the set point temperature as quickly as possible and the temperature gradient adjustment is to prolong the time for the chamber temperature to reach the set point temperature, as a result, the time for the chamber temperature to reach the set point temperature cannot be made faster.

Yes, if ordered, it is possible to install a socket for FG incubators.

Since incubators usually work at 5 degrees above the ambient temperature, this doubt arises for consumers that if the temperature of the laboratory environment is, for example, 20 degrees, a thermal incubator can be used for a temperature of 30 degrees. But since the temperature The environment cannot be controlled. The standards emphasize the use of refrigerated incubators for temperatures close to the ambient temperature, because the ambient temperature may become hotter, and the incubator device must also be capable of cooling the chamber.

Yes, a special mechanism has been considered for the air discharge process and the entry of fresh air into the incubator chamber, which causes the maximum discharge of moisture and gases created in the chamber.

Yes, if needed, you can move the trays according to the different drawers installed in the incubator.

Yes, if needed, you can move the trays according to the different drawers installed in the oven.

Yes, if needed, you can move the trays according to the different drawers installed in the incubator.

ask us

If you still haven’t found the answer to your question, ask us.

"*" indicates required fields

first name and last name*

Other FG products

To see another FG products. Refer to the products page.

All products

The latest news and blogs

Leave a Reply

Your email address will not be published.Required fields are marked *