Introducing the new generation of FG Smart laboratory incubator
The most accurate incubator in the world with unique isotherm in accordance with the most reliable international standards
Fast temperature recovery to the set temperature after opening the door
Better temperature uniformity and faster heating with the second generation HCT
Temperature uniformity at 27 points in the chamber
Temperature stability
Triple-layered design
Double safety to protect your samples against unwanted increase or decrease in temperature
Compliant with the latest (TWW) DIN 12880 Class 3.1 standards
Adjustable safety thermostat with a separate sensor
Temperature control in case of unintended increase
Equipped with two PT100 sensors

Laboratory incubator introduction video
To get to knowMore details about FG laboratory ovenWatch the opposite video.
Table of technical specifications laboratory incubator
Customized equipment and services
Perforated stainless steel tray
Custom dimensions and temperature options available
Installation of custom number and diameter of vents
Glass door with metal frame
IQ, OQ, PQ certifications
Calibration certificate provided
Built-in lighting
Mesh tray
No, the mechanism of the air release valve is the maximum exit of vapors and gases created in the chamber. But the circulator fan is used to accelerate the air circulation inside the chamber.
It always takes time for the internal chamber temperature to reach the set point. The smart timer is activated when the temperature reaches the set point.
Using a safety thermostat in FG devices, which acts like a fuse and turns off the incubator if the temperature exceeds the set point.
According to FG standards and the world’s valid standards, the best distance from the walls, floor and ceiling of the incubator is 10% of the length of the same side, for example, if the width of the device is 40 cm, 10% is 4 cm on each side (left and right). And if the depth of the device is 50 cm, 10% of it, that is, 5 cm from the front and back, should be considered the distance from the walls of the device for loading.
Yes, with the help of the HCT technology used in the incubator, you will have full isothermal even in the full load mode of the device (according to the loading principles).
The incubator device reaches the set point temperature as quickly as possible and the temperature gradient adjustment is to prolong the time for the chamber temperature to reach the set point temperature, as a result, the time for the chamber temperature to reach the set point temperature cannot be made faster.
Yes, if ordered, it is possible to install a socket for FG incubators.
Since incubators usually work at 5 degrees above the ambient temperature, this doubt arises for consumers that if the temperature of the laboratory environment is, for example, 20 degrees, a thermal incubator can be used for a temperature of 30 degrees. But since the temperature The environment cannot be controlled. The standards emphasize the use of refrigerated incubators for temperatures close to the ambient temperature, because the ambient temperature may become hotter, and the incubator device must also be capable of cooling the chamber.
Yes, a special mechanism has been considered for the air discharge process and the entry of fresh air into the incubator chamber, which causes the maximum discharge of moisture and gases created in the chamber.
Yes, if needed, you can move the trays according to the different drawers installed in the incubator.
Yes, if needed, you can move the trays according to the different drawers installed in the oven.
Yes, if needed, you can move the trays according to the different drawers installed in the incubator.
If you still haven’t found the answer to your question, ask us.
"*" indicates required fields