Smart Laboratory Incubator

Smart Laboratory Incubator

Introducing the new generation of FG Smart laboratory incubator

The most accurate incubator in the world with unique uniformity in accordance with the most reliable international standards

Quick return of the temperature to the set temperature after opening the device door

Better Uniformity and faster heating with the second-generation HCT

Uniformity @ 27 points of the chamber

Temperature stability

dual chamber

Double safety to protect your samples against unwanted increase or decrease in temperature

According to the latest standards of (TWW) DIN 12880 Class 3.1

Adjustable safety thermostat with separate sensor

Temperature control in case of unwanted increase

Two PT100 sensors

Laboratory incubator introduction video

To get to know More details about FG laboratory Oven Watch the opposite video.

Product video gallery
Table of technical specifications of laboratory incubator CF & CM model
Image link
External specifications
CM55
CM120
CF240
CF700
Minimum allowed distance from walls and adjacent devices (cm)
16
The minimum distance allowed from the back wall (cm)
10
10
10
20
Minimum clearance above the device (cm)
5
5
5
40
Depth (with handle and controller) (G) (cm)
60
73
74
90
Depth (without handle) (F) (cm)
54.5
67.5
69
85
Height of the device with base (E) (cm)
63.5
68
104
191
Device width (D) (cm)
64.5
82.5
90
121
Device weight (kg)
43
61
98
300
number of doors
1
1
1
2
Image link
Internal specifications
CM55
CM120
CF240
CF700
Internal volume (LIT)
50
Height (B) (cm)
41.5
46
80.5
128
Width (A) (cm)
41
59
66.5
97
Depth (C) (cm)
29.5
42
42.5
57
Weight capacity for each tray (kg)
30
30
40
40
Ability to bear the weight of the entire floor (kg)
60
100
150
250
Number of standard trays available in the machine – (maximum)
2 – (4)
2 – (5)
2 – (8)
2 – (14)
circulating fan
have not
have not
have
have
Heat information
CM55
CM120
CF240
CF700
Thermal range: 5 degrees above ambient temperature (at least 20 degrees) to (C˚)
80°C
Display Accuracy at 37°C (Deviation: ±K)
±0.1
±0.1
±0.1
±0.1
Display accuracy at temperature (deviation) (K±) 55°C
±0.1
±0.1
±0.1
±0.1
Display Accuracy at 70°C (Deviation: ±K)
±0.1
±0.1
±0.1
±0.1
Temperature Fluctuation at 37°C: ±K
±0.2
±0.2
±0.2
±0.5
Temperature fluctuation (K±) 55°C
±0.2
±0.2
±0.3
±0.6
Temperature Fluctuation at 70°C: ±K
±0.2
±0.2
±0.3
Temperature Control Accuracy
±0.1
±0.1
±0.1
Uniformity at 27 points of the chamber (Variation)
CM55
CM120
CF240
CF700
Temperature Uniformity at 37°C: ±K
±0.5
±0.6
±0.8
Isothermal at (variation) (K±) 55°C
±0.6
±0.6
±1.0
±1.5
Temperature Uniformity at 70°C: ±K
±0.5
±0.7
±2.0
The speed of reaching the temperature (heating-up time)*
CM55
CM120
CF240
CF700
Time to Reach 37°C (min)
55
Time to Reach 55°C (min)
95
Time to Reach 70°C (min)
100
Returning the temperature to the Set temperature after opening the device door for 30 seconds (*) (Recovery time)
CM55
CM120
CF240
CF700
Temperature Recovery Time at 37°C (min)
30
Temperature Recovery Time at 55°C (min)
35
35
8
35
Temperature Recovery Time at 70°C (min)
40
45
32
Electrical information
CM55
CM120
CF240
CF700
power consumption (W)
400
Frequency (HZ)
50
50
50
50
Voltage (V AC)
220
220
220
220
flow
1.8
1.8
5
10
type of electricity
single phase
single phase
single phase
single phase
Image link
Image link
Image link
Image link
Customized equipment and services

Tray made of mesh stainless steel sheet

Manufacturing based on custom dimensions and temperatures

Installation of valves in customized number and diameter

Glass door with metal frame

IQ, OQ, PQ Certificates

Calibration Certificate

Light bulb

net tray

No, the mechanism of the air release valve is the maximum exit of vapors and gases created in the chamber. But the circulator fan is used to accelerate the air circulation inside the chamber.

It always takes time for the internal chamber temperature to reach the set point. The Smart timer is activated when the temperature reaches the set point.

Using a safety thermostat in FG devices that acts like a fuse and turns off the incubator device if the temperature rises above the set point.

According to FG standards and valid world standards, the best distance from the walls, floor, and ceiling of the incubator is 10% of the length of the same side. And if the depth of the device is 50 cm, 10% of it, that is, 5 cm from the front and back, should be considered the distance from the walls of the device for loading.

Yes, with the help of the HCT technology used in the incubator, you will have full uniformity even when the device is fully loaded (in accordance with the loading principles).

The incubator device reaches the set point temperature as quickly as possible and the temperature gradient adjustment is to prolong the time for the chamber temperature to reach the set point temperature, as a result, the time for the chamber temperature to reach the set point temperature cannot be made faster.

Yes, it is possible to install sockets for FG incubators upon request.

Since incubators usually work at 5 degrees above the ambient temperature, this doubt arises for consumers that if the temperature of the laboratory environment is, for example, 20 degrees, a thermal incubator can be used for a temperature of 30 degrees. But since the temperature The environment cannot be controlled. The standards emphasize the use of a refrigerated incubator for temperatures close to the ambient temperature, because the ambient temperature may become hotter, and the incubator device must also be capable of cooling the chamber.

Yes, a special mechanism has been considered for the air evacuation process and the entry of fresh air into the incubator chamber, which causes the maximum evacuation of moisture and gases created in the chamber.

Yes, if needed, you can move the trays according to the different drawers installed in the incubator.

Yes, if needed, you can move the trays according to the different drawers installed in the oven.

No, if you need more trays in the incubator, you can use more space just by buying a tray, and there is no need to pay extra for installing rails or other changes in the device.

ask us

If you still haven’t found the answer to your question, ask us.

"*" indicates required fields

first name and last name*
FG products

To see another FG products. Refer to the products page.

All products
The latest news and blogs

Leave a Reply

Your email address will not be published.Required fields are marked *