Stability test chamber

Stability test chamber

Stability test chamber

The ZF model Stability Test Chamber (or Temperature and Humidity Chamber) is an ideal device for conducting stability tests in compliance with the ICH Q1A(R2) guideline. Featuring simultaneous control of temperature and humidity, this chamber ensures precise and reliable testing conditions. Its advanced data logging and control system, fully compliant with international standards such as GMP and GLP, sets it apart from similar devices worldwide.

sms alarm

The FG Stability Test Chamber is used in a wide range of laboratories, including: Industrial Pharmaceutical Investigation It is applicable.

Introduction of the New Generation of FG Stability Test Chambers

The most accurate chamber in the world with unique isotherm in accordance with the most reliable international standards

Quick return of the temperature to the set temperature after opening the device door

Uniformity @ 27 points of the chamber

High heating speed

Temperature stability

dual chamber

Double safety to protect your samples against unwanted increase or decrease in temperature

Adjustable safety thermostat with sensors (with two PT100 sensors)

According to the latest standards (TWW) DIN 12880 Class 3.3

The pleasure of using the most accurate cooling system in the world

The pleasure of using the most accurate cooling system in the world

Unparalleled cooling power even at high ambient temperature

No thrush

2 evaporator

The most resistant humidifier without deposits on the sensors

Prevention of Chemical Reactions and Corrosion of Water Level Sensors

To prevent water scaling on electronic sensors

Using electronic sensors to control the water level

Temperature and humidity chamber humidifier system

Unique humidifier system

Inlet and outlet water source with separate pump (no need for inlet water and sewage piping)

Rapid return of humidity to the set value after opening the door

With extra water pump

The ability to precise adjust the humidity

Creating moisture at high speed

Accurate humidity sensor

Using the latest and most accurate ARM series microcontrollers

Controller lock system to prevent accidental changes

Graphical LCD display with touch buttons

Easy humidity calibration by the user in 2 humidity points

Easy temperature calibration by the user in 6 temperatures

PID controller to control temperature and humidity

Controller with 3 programs of 100 steps

Smart STM Temperature Check

Intelligent alarm of deviation from the set temperature and humidity

Discharge or Decrease of Water alarm

Device door open alarm

Sending SMS during alarms

Register DOCUMENTATION values

Internal memory to record temperature, humidity and fan speed values for up to 2 years
Recording values according to GMP and GLP standards
Drawing a graph of temperature and humidity on the device's LCD

FGLAB software

The ability to print graphs in a specific time frame in accordance with GMP and GLP standards, without the need to install intermediate software, the ability to connect the device to a computer, the ability to view values online,

Product video

To get to know More details of the product Watch the opposite video.

Product video gallery

ZF technical specifications table

Exterior dimensions
ZF120
ZF240
ZF400
ZF700
ZF1400
Depth Plus water supply, door handle (cm) (G)
 
95
95
120
129
Depth plus controller (cm)(F)
 
75
75
75
90
112
Height (incl. feet) (cm) (E)
 
106
148
204
200
205
Width (cm) (D)
 
82.5
90
90
121
161
Number of doors
 
1
1
1
2
2
Interior dimensions
ZF120
ZF240
ZF400
ZF700
ZF1400
Interior volume (L)
 
124
400
700
1342
Width (cm) (A)
 
59
66
66
97
136
Depth (cm) (C)
 
46
45.5
45.5
57
77
Weight (empty) (Kg)
 
115
150
220
325
-
Load per rack (Kg)
 
30
40
40
40
45
Permitted total load (Kg)
 
100
150
200
250
300
Racks number standard (max)
 
2-(4)
2-(8)
2-(15)
2-(14)
2-(14)
Climatic data
ZF120
ZF240
ZF400
ZF700
ZF1400
Recovery time after door were open for 30 sec @ 25 (◦C) and 60% RH (min)
 
10
10
20
20
Temperature uniformity @ 25◦C without humidity (±K)
 
±1
±1
±1
±1
±1
Temperature uniformity @ 25◦C with humidity (±K)
 
±1
±1
±1
±1
±1
Temperature fluctuation @ 25◦C without humidity (±K)
 
±0.5
±0.5
±0.7
±0.5
±0.5
Temperature fluctuation @ 25◦C with humidity (±K)
 
±1
±1
±1
±1.5
±1.5
Temperature fluctuation @ 40◦C without humidity (±K)
 
±0.6
±0.6
±0.6
±0.6
±0.6
Temperature fluctuation @ 40◦C with humidity (±K)
 
±0.6
±0.8
±1
±1.5
±1.5
Temperature uniformity @ 40◦C without humidity (±K)
 
±1.5
±1.5
±1
±1.5
±1.5
Temperature uniformity @ 40◦C with humidity (±K)
 
±1.5
±1.5
±1.5
±1.5
±1.5
Temperature range without humidity (◦C)
 
0-60
0-60
0-60
0-60
0-60
Display accuracy at @40°C (Deviation) (±K)
 
±0.2
±0.2
±0.2
±0.2
±0.2
Temperature range with humidity (◦C)
 
10-60
10-60
10-60
10-60
10-60
Humidity fluctuation (%RH)
 
±5
±5
±5
±5
±5
Humidity range (%RH)
 
10-80
10-80
10-80
10-80
10-80
Installation conditions
ZF120
ZF240
ZF400
ZF700
ZF1400
Wall clearance, side (cm)
 
15
15
15
15
Wall clearance, above (cm)
 
30
40
40
40
40
Wall clearance, rear (cm)
 
20
20
20
20
20
Minimum and Maximum ambient temperature (◦C)
 
+16 to +26
+16 to +26
+16 to +26
+16 to +26
+16 to +26
Maximum ambient humidity (%RH)
 
70
70
70
70
70
Electrical data
ZF120
ZF240
ZF400
ZF700
ZF1400
Power (W)
 
1540
3300
3750
4000
Frequency (HZ)
 
50
50
50
50
50
Voltage (V AC)
 
220
220
220
220
220
Current (A)
 
7
12
15
17
18.2

Customized equipment and services

IQ, OQ, PQ Certificates

Stainless steel tray

Alarm output relay

Network switch

Wi-Fi switch

Modem

Frequently Asked Questions(FAQ)

Considering that the water source of stability chambers is separate from the device, it is possible to disconnect the source from the device when entering the laboratory and reconnect it after installing the device, in which case the depth of the device without the source will be equal to 75 cm.

According to FG standards and the world’s valid standards, the best distance from the walls, floor and ceiling of the stability test chamber is 10% of the length of the same side, for example, if the width of the device is 40 cm, 10% is 4 cm from each side (left and right). ) and if the depth of the machine is 50 cm, 10% of that means 5 cm from the front and back, the distance from the walls of the machine should be considered for loading.

It always takes time for the internal chamber temperature to reach the set point. The Smart timer is activated when the temperature reaches the set point.

Since many centers do not have facilities such as water or sewage pipes, a feature has been placed in the FG stability chambers so that they can be installed and work properly independently of the deficiencies of the environment. Therefore, the FG stability test chamber is equipped with an inlet water source. And it is an exit and does not need plumbing.

Alarms should be such as to attract the user’s attention. Now imagine a device that repeatedly and unnecessarily alarms, such as when the door of the device is opened (naturally, the temperature of the device goes higher or lower). In normal devices, the alarm is activated, but in the FJ device, the alarm is activated only when it is needed and in The malfunctioning device is activated.

No, by using HCT technology, instead of water vapor entering the chamber, moist air enters the device, which prevents the samples from getting wet.

Yes, it can be done if needed by the consumers and according to the request.

Relative humidity has a direct relationship with heat, so there are always restrictions on devices that control both temperatures and humidity. FG devices are no exception, so it is recommended to chart the humidity temperature in the database of the devices FG is referred to.

ask us

If you still haven’t found the answer to your question, ask us.

"*" indicates required fields

first name and last name*

FG products

To see another FG products. Refer to the products page.

All products

The latest news and blogs

Leave a Reply

Your email address will not be published.Required fields are marked *